DOWNHOLE CASING HISTORIES
APPLICATION New San Andreas Water Injection Wells completed with Fiberglass Casing
LOCATION Bennet Ranch near Denver City, Texas
PRODUCT 5 1/2" 2000 psi Casing, Threaded and Coupled
QUANTITY 20 Wells completed since 1987
500 ft. to 1500 ft. of Fiberglass Casing used in the pay area of each well
SERVICE
CONDITIONS
Total depth 5200 ft. average, cemented in place with DV tool.  Jet perforated, 2 to 4 shots per ft., hollow carrier 10 to 13 gram select fire charges,  Water Injection Pressure 1400 psi.  Water contains polysulfide and iron sulfide, gradient 0.43.  Reservoir Pressure 2600 psi.  Bottom Hole Injection Pressure 3550 psi, Bottom Hole Temp. 55 deg. F to 105 deg. F. cup type packers set in some of the fiberglass.  Certain wells were installed with CRA joint above fiberglass for packer setting.  Steel ran above CRA or fiberglass.

APPLICATION Fiberglass Tubing successfully repairs corroded 4 1/2" steel casing
LOCATION Near Eagle Pass, Texas
PRODUCT 2 7/8" 2500 psi Tubing, Threaded and Coupled with special O.D. Turned Down Collars
QUANTITY 42 Wells completed in 1991, 36 Wells completed in 1992
SERVICE
CONDITIONS
Approximately 1300 to 1700 ft. ran top to bottom in each well.  Water Injection 1000 psi, Injection Temp. 85 deg. F, Bottom Hole Temp. 100 deg. F.  The pipe is sandblasted and cemented in place.  Inflatable packers used in first 42 wells, used two joints of steel on the bottom, the steel was perforated.  The 36 wells completed in 1992 were installed using a polished bore receptacle with a latch instead of an inflatable packer.  A special cement shoe was used on these 32 wells and the liner was stopped above the original perforations.  This saved the cost of two joints of steel tubing, perforating and acidizing.

APPLICATION Fiberglass Casing and Liners in service up to 20 years
LOCATION Denver City, Texas
PRODUCT 3 1/2" & 4 1/2" 2000 psi Tubing, Threaded and Coupled (used for liner repair of corroded steel casing)
5 1/2" 2000 psi Casing, Threaded and Coupled (used in new wells at the bottom of a steel string)
QUANTITY 350 Injection Wells completed since 1971 at the Denver Unit
The fiberglass is ran through the corrosive pay area
SERVICE
CONDITIONS
Total well depth 5200 ft., 500 ft. to 1500 ft. of fiberglass cemented in place and perforated.  Co2 and Water Wag System began in 1984.  Co2 Surface Injection 1800 psi, Water Injection Pressure 1400 psi.  Bottom Hole Temp. 55 deg. F to 105 deg. F.

APPLICATION High Temperature Observation Well Casing
LOCATION Dubai - October 1992
PRODUCT 5 1/2" 2000 psi Casing, Threaded and Coupled
QUANTITY 416 ft.
SERVICE
CONDITIONS
Observation Well Offshore
Total depth 9,305 ft.
Fiberglass Casing from 9,134 to 8,718 ft.
BH temperature 235 deg. F.
Cemented to surface.  Wireline Tools

APPLICATION Japan - September 1993
PRODUCT 7" 2000 psi Casing, Threaded and Coupled ACT
SERVICE
CONDITIONS
Oil and Gas Production total depth 6,090 ft.
13 3/8" Steel Surface Casing 1,410 ft.
Fiberglass Casing ran from 1,410 ft. to 6,090ft.
41 degree deviation cemented from 4,055 ft. to surface
Perforated 7" fiberglass Casing with wire screen ran from 4,055 to 6,090 ft.

APPLICATION Special sized Carbon Fiber Coupling's increase liner size while maintaining performance
LOCATION Oosaka, Japan
PRODUCT 5 1/2" 1500 spi Casing O.D. 5.80" Carbon Fiber Coupling - 1,410 ft.
7" 1500 psi Casing combination tapered string cemented in place - 1,260 ft.
SERVICE
CONDITIONS
Installed in September 1993
 

 

TOP
HOME  |  downhole tubing/casing  |  line pipe  |  fittings engineering data  |  accessories  |  applications  |  case histories